logo
Αρχική Σελίδα Προϊόνταultrafiltration μεμβράνη

Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module

Πιστοποίηση
Κίνα Sinomemb Environment Technology (beijing) Co., Πιστοποιήσεις
Κίνα Sinomemb Environment Technology (beijing) Co., Πιστοποιήσεις
Είμαι Online Chat Now

Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module

Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module
Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module

Μεγάλες Εικόνας :  Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module

Λεπτομέρειες:
Τόπος καταγωγής: ΚΙΝΑ
Μάρκα: SINOMEMB
Πιστοποίηση: NSF
Αριθμό μοντέλου: SNU-HO-2860
Πληρωμής & Αποστολής Όροι:
Ποσότητα παραγγελίας min: 5
Συσκευασία λεπτομέρειες: Τυπική συσκευασία εξαγωγής

Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module

περιγραφή
Υλικό μεμβράνης: PVDF/PES Λειτουργία διήθησης: Διασταυρούμενη ροή
Βασικά στοιχεία: UF Επενδύσεις Στέγαση: UPVC
Εφαρμογή: Ηλεκτροφορητική συγκέντρωση βαφής
Επισημαίνω:

Seawater ultrafiltration membrane module

,

Wastewater ultrafiltration membrane module

,

UPVC Housing UF Membrane Module

The core SINOMEMB ® series SNU-HO-2-860 hollow fiber UF membrane element is suitable for systems with a capacity greater than 50m 3 /hr (220 gpm) . Compared with longer membrane modules, shorter membrane modules (60 inches) provide higher separation efficiency and can adapt to a wider range of influent water quality , helping customers to achieve more economical membrane system design , and can be widely used on the surface Various water treatment applications such as water, well water, seawater , industrial wastewater, and secondary and tertiary treatment of sewage .

Ø Membrane element specifications

Membrane element model

Effective membrane area

ft 2 (m 2 )

Effective volume

G( L )

weight empty /full of water

( kg )

SN U-HO-2-860 539(50) 9.3(35) 48/83
Inlet size Water outlet size Concentrated water outlet size Membrane Polymer
DN50 DN50 DN50 PVDF
Membrane inner diameter/outer diameter (mm) Filtration precision (μ m ) shell material Sealant material
0.7/1.3 0.03 U-PVC epoxy resin
  • Membrane element operating parameters
Filtration flux ( 25℃ ) L/㎡·hr 40-120
Flow range m³/hr 2.0-6.0
Maximum influent turbidity (NTU) ≤300
Maximum resistance to residual chlorine (NaCLO) (ppm) Continuous: 200; Momentary: 2000
Maximum anti-suspended solid capacity (ppm) ≤100
Maximum influent particle size ( μm ) 300
Working temperature (℃) 1-40
pH range 2-11
Maximum water production (L/m³·h) 150
Maximum inlet pressure (Mpa) 0.625
Maximum transmembrane pressure difference (Mpa) 0.21
Maximum backwash pressure (Mpa) 0.25
Maximum air flushing flow rate (Nm³/hr) 12
General backwash cycle (min) 15-60
General backwash time (sec) 30-60
General backwash flow rate (L/m³·h) 100-360
General chemical enhanced backwash cycle (day) 1-15
General chemical backwashing time (min) 1-15
General chemical cleaning cycle (day) 30-180
General chemical cleaning time (min) 90-480
General chemical cleaning chemicals NaClO or H2O2 500ppm , NaOH (PH≤13), HCl (PH≥1 )
How to run /operate outside-in / full flow or cross flow filtration
Expected water production SDI ≤2.5
Expected product water turbidity NTU ≤0.1
Bacteria removal rate (log) >6
E. coli removal rate (log) >6
service life ≥3 years under standard conditions

 

Ø UF membrane element size

Seawater Wastewater Ultrafiltration Membrane Module UPVC Housing UF Membrane Module 0

L L1 L2 L3 L4 Diameter Φ air intake
1860mm 1500mm 1630mm 1820mm 180mm 225mm RP 3/8”
(73.2)in (59.1)in (64.2)in (71.7)in (7.1)in (8.9)in /

Ø Operation Guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum withstand pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Ø Product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Ø Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

Στοιχεία επικοινωνίας
Sinomemb Environment Technology (beijing) Co.,

Υπεύθυνος Επικοινωνίας: Mr. Gary Gao

Τηλ.:: +8618610069839

Στείλετε το ερώτημά σας απευθείας σε εμάς (0 / 3000)

Άλλα προϊόντα