logo
제품 소개한외 여과막

Customized Ultrafiltration Membrane Module Stable Operation Space Saving

인증
중국 Sinomemb Environment Technology (beijing) Co., 인증
중국 Sinomemb Environment Technology (beijing) Co., 인증
제가 지금 온라인 채팅 해요

Customized Ultrafiltration Membrane Module Stable Operation Space Saving

Customized Ultrafiltration Membrane Module Stable Operation Space Saving
Customized Ultrafiltration Membrane Module Stable Operation Space Saving Customized Ultrafiltration Membrane Module Stable Operation Space Saving Customized Ultrafiltration Membrane Module Stable Operation Space Saving Customized Ultrafiltration Membrane Module Stable Operation Space Saving

큰 이미지 :  Customized Ultrafiltration Membrane Module Stable Operation Space Saving

제품 상세 정보:
원래 장소: 중국
브랜드 이름: SINOMEMB
인증: NSF
모델 번호: SNU-HO-2-660
결제 및 배송 조건:
최소 주문 수량: 5
포장 세부 사항: 표준 수출 포장

Customized Ultrafiltration Membrane Module Stable Operation Space Saving

설명
핵심 구성 요소: UF 막 애플리케이션: 폐수 처리장 장비를위한 산업용 세라믹 멤브레인, 상업, 산업, 수처리
재료: PVDF, 순수한 AL2O3 (99%이상), PES/PS/PVC/PAN, 스테인리스 스틸/PVC, PP/PAN/PVDF/PS 제품명: 중공 광섬유 한외 여과막, Ultrafiltration System, PVC 중공 섬유 UF 막 모듈
기공 크기: 맞춤형., 1μm 내지 0.05μm, 0.01micron, 1.0μm, 0.2μm 용법: 수처리, 해수 이온화제 담수화, 액체 필터, 박테리아 제거, 정제
강조하다:

Customized ultrafiltration membrane module

,

Stable ultrafiltration membrane module

,

Customized PVDF UF Membrane

n SINOMEMB ® UF membrane module SNU-HO-2-660 type

The core SINOMEMB ® series SNU-HO-2-660 hollow fiber UF membrane element membrane module is ideal for systems with a capacity of 50 m 3 /hr (220 gpm) and below. The 60-inch length of this module is more effective at treating a variety of feedwaters than longer modules. In addition, the diameter of the membrane module is 6 inches , and the size is small, which can realize a relatively compact design , which is very suitable for occasions with limited space . The excellent performance helps customers to achieve a more economical membrane system design , and can be widely used in surface water , well water, seawater , industrial wastewater, secondary and tertiary treatment of sewage and other water treatment applications.

Ø Membrane element specifications

Membrane element model

Effective membrane area

ft 2 (m 2 )

Effective volume

G( L )

weight empty /full of water

( kg )

SN U-HO-2-660 355(33) 4.2(16) 25/41
Inlet size Water outlet size Concentrated water outlet size Membrane Polymer
DN50 DN50 DN32 PVDF
Membrane inner diameter/outer diameter (mm) Filtration precision (μ m ) shell material Sealant material
0.7/1.3 0.03 U-PVC epoxy resin

Ø Membrane element operating parameters

Filtration flux ( 25℃ ) L/㎡·hr 40-120
Flow range m³/hr 1.3-4.0
Maximum influent turbidity (NTU) ≤300
Maximum resistance to residual chlorine (NaCLO) (ppm) Continuous: 200; Momentary: 2000
Maximum anti-suspended solid capacity (ppm) ≤100
Maximum influent particle size ( μm ) 300
Working temperature (℃) 1-40
pH range 2-11
Maximum water production (L/m³·h) 150
Maximum inlet pressure (Mpa) 0.625
Maximum transmembrane pressure difference (Mpa) 0.21
Maximum backwash pressure (Mpa) 0.25
Maximum air flushing flow rate (Nm³/hr) 12
General backwash cycle (min) 15-60
General backwash time (sec) 30-60
General backwash flow rate (L/m³·h) 100-360
General chemical enhanced backwash cycle (day) 1-15
General chemical backwashing time (min) 1-15
General chemical cleaning cycle (day) 30-180
General chemical cleaning time (min) 90-480
General chemical cleaning chemicals NaClO or H2O2 500ppm , NaOH (PH≤13), HCl (PH≥1 )
How to run /operate outside-in / full flow or cross flow filtration
Expected water production SDI ≤2.5
Expected product water turbidity NTU ≤0.1
Bacteria removal rate (log) >6
E. coli removal rate (log) >6
service life ≥3 years under standard conditions

Ø UF membrane element size

Customized Ultrafiltration Membrane Module Stable Operation Space Saving 0

L L1 L2 L3 L4 Diameter Φ air intake
1860mm 1500mm 1610mm 1710mm 125mm 165mm RP 3/8”
(73.2)in (59.1)in (63.4)in (67.3)in (4.9)in (6.5)in /

Ø Operation Guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Ø Product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Ø Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

연락처 세부 사항
Sinomemb Environment Technology (beijing) Co.,

담당자: Mr. Gary Gao

전화 번호: +8618610069839

회사에 직접 문의 보내기 (0 / 3000)