logo
Casa ProdutosMembrana MBR

SNU-HM hollow fiber submerged curtain UF

Certificado
China Sinomemb Environment Technology (beijing) Co., Certificações
China Sinomemb Environment Technology (beijing) Co., Certificações
Estou Chat Online Agora

SNU-HM hollow fiber submerged curtain UF

SNU-HM hollow fiber submerged curtain UF
SNU-HM hollow fiber submerged curtain UF SNU-HM hollow fiber submerged curtain UF SNU-HM hollow fiber submerged curtain UF

Imagem Grande :  SNU-HM hollow fiber submerged curtain UF

Detalhes do produto:
Lugar de origem: CHINA
Marca: SINOMEMB
Certificação: NSF
Número do modelo: Snu-hm
Condições de Pagamento e Envio:
Quantidade de ordem mínima: 5
Detalhes da embalagem: Embalagem de exportação padrão

SNU-HM hollow fiber submerged curtain UF

descrição
Componentes principais: MBR Nome do produto: membrana de ultrafiltração de fibra oca, sistema de ultrafiltração, módulo de membrana de fibra oca
Tamanho de poro: personalizado., de 1μm a 0,05μm, 0,01micron, 1,0μm, 0,2μm Uso: Tratamento de águas residuais, filtro líquido, remova bactérias, purificação
Módulo: Externo Tamanho nominal dos poros: 0,1 μm
Estrutura da membrana: Fibra oca Material da membrana: PVDF
Superfície: 10-100 m2
Destacar:

pvdf mbr membrane

,

customized mbr membrane

SNU-HM hollow fiber submerged curtain UF

SNU-HM type hollow fiber submerged curtain UF adopts a special patented technology in the spinning process and adds a reinforced reinforced lining, so it has all the advantages of PVDF material membrane filaments, but also has high strength and toughness. specialty. This feature fundamentally makes up for the biggest shortcoming of the traditional PVDF membrane, which is low in strength, easy to break, and cannot be well adapted to high-intensity aeration environments. It is of great milestone significance for the application of PVDF membrane in the MBR process. At the same time, since the design flux of the SNU-HM hollow fiber submerged curtain UF membrane is generally set to an appropriate value according to different water qualities, its online cleaning cycle is relatively long, about 7 to 17 days.

Membrane element specifications and main performance

model SNU-HM-Ⅰ SNU-HM-Ⅱ
Specifications ( mm ) 630×1500×36 630×2000×36
Membrane inside and outside diameter ( mm ) 1.5/2.6 0.8/1.4
Effective membrane area (㎡) 15 20
Filtration precision (μ m ) 0.05
Membrane material U-PVC/ABS
membrane material Modified PVDF (polyvinylidene fluoride) and PET (polyester) support tubes
Connecting pipe specification Φ32
Water collection method Water catchment at both ends
filter method Submerged Suction Filtration
PH value 2-12
temperature (°C) 10-45
Oil content ( ppm ) <3
Transmembrane pressure TMP (Mpa) 0.02-0.05
Backwash pressure (Mpa) 0.1
Aeration rate ( m³/h ) Air-water ratio 15:1-20:1
Backwash water flux ( L/㎡·h ) 25-50 25-36
Collecting pipe center distance (mm) 1500
Sludge concentration ( ppm ) 4000-12000 3000-10000
Design flux ( L/㎡·h ) 15-25 12-18
Product water quality Turbidity≤0.2NTU, SDI≤3
service life ≥3 years under standard conditions

n UF membrane element size

SNU-HM hollow fiber submerged curtain UF 0

Operation Guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum withstand pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

 Product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

Contacto
Sinomemb Environment Technology (beijing) Co.,

Pessoa de Contato: Mr. Gary Gao

Telefone: +8618610069839

Envie sua pergunta diretamente para nós (0 / 3000)

Outros Produtos