logo
Inicio Productosmembrana de la ultrafiltración

220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water

Certificación
China Sinomemb Environment Technology (beijing) Co., certificaciones
China Sinomemb Environment Technology (beijing) Co., certificaciones
Estoy en línea para chatear ahora

220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water

220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water
220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water 220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water 220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water 220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water

Ampliación de imagen :  220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water

Datos del producto:
Lugar de origen: PORCELANA
Nombre de la marca: SINOMEMB
Certificación: NSF
Número de modelo: SNU-HI-1-H 60
Pago y Envío Términos:
Cantidad de orden mínima: 5
Detalles de empaquetado: Embalaje de exportación estándar

220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water

descripción
Componentes centrales: UF Acero Solicitud: Membrana de cerámica industrial, comercio, industria, tratamiento de agua, equipos de plantas de tra
Nombre del producto: Membrana de ultrafiltración de fibra hueca, sistema de ultrafiltración, módulo de membrana de fibra Tamaño de poro: personalizado., de 1 μm a 0.05 μm, 0.01micron, 1.0 μm, 0.2 μm
Uso: tratamiento de agua, desalinización del ionizador de agua de mar, filtro de líquido, eliminar las ba Módulo: De adentro hacia fuera
Tamaño nominal del poro: 0,1 μm Estructura de la membrana: Fibra hueca
Material de membrana: Polyethersulfone (PES) Área total de la membrana: 30 metros cuadrados
Resaltar:

220gpm Hollow Fibre UF Membrane

,

Surface Water Hollow Fibre UF Membrane

,

Well Water PES UF Membrane

SINOMEMB ® UF membrane module SNU-HI-1-H 60 type

The core SINOMEMB ® series SNU-HI-1-H 60 hollow fiber UF membrane element is suitable for high turbidity raw water systems with a capacity of more than 50 m 3 /hr (220gpm) . Longer module length, larger effective membrane area, and greater packing density make it one of the modules with the highest effective membrane area in SINOMEMB ® series UF modules , helping customers to achieve more economical membranes The system design can be widely used in various water treatment applications such as surface water, well water, seawater , industrial wastewater, and sewage secondary and tertiary treatment .

Ø Membrane element specifications

Membrane element model

Effective membrane area

ft 2 (m 2 )

Effective volume

G( L )

weight empty /full of water

( kg )

SNU-HO-2-H MAX60 500(46) 10(37) 52/100
Inlet size Water outlet size Concentrated water outlet size Membrane Polymer
DN50 DN50 DN50 PES
Membrane inner diameter/outer diameter (mm) Filtration precision (μ m ) shell material Sealant material
0.8/1.4 0.02 U-PVC epoxy resin

Ø Membrane element operating parameters

Filtration flux ( 25℃ ) L/㎡·hr 59-145
Flow range ( 25℃ ) m³/hr 2.7-6.7
Maximum influent turbidity (NTU) ≤50
Maximum resistance to residual chlorine (NaCLO) (ppm) Continuous: 50; Momentary: 200
Maximum anti-suspended solid capacity (ppm) ≤50
Maximum influent particle size ( μm ) 100
Working temperature (℃) 1-40
pH range 1-13
Maximum water production (L/m³·h) 150
Maximum water inlet pressure ( 20°C ) (Mpa) 0.5
Maximum transmembrane pressure difference (Mpa) 0.14
Maximum backwash pressure (Mpa) 0.25
Maximum air flushing flow rate (Nm³/hr) /
General backwash cycle (min) 15-60
General backwash time (sec) 30-60
General backwash flow rate (L/m³·h) 170-255
General chemical enhanced backwash cycle (day) 1-15
General chemical backwashing time (min) 1-15
General chemical cleaning cycle (day) 30-180
General chemical cleaning time (min) 90-480
General chemical cleaning chemicals NaClO or H2O2 500ppm , NaOH (PH≤13), HCl (PH≥1 )
How to run /operate inside-out / full flow or cross flow filtration
Expected water production SDI ≤2.5
Expected product water turbidity NTU ≤0.07
Bacteria removal rate (log) >4
E. coli removal rate (log) >4
service life ≥3 years under standard conditions

Ø Membrane element size

220gpm Hollow Fibre UF Membrane Treatment For Surface Water Well Water 0

A B C Diameter Φ
1600mm 1680mm 1708mm 225mm
(63)in (66)in (67)in (8.9)in

Ø Membrane element operation guide

During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

Ø Membrane element product usage tips

The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

Ø Disclaimer

Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

Contacto
Sinomemb Environment Technology (beijing) Co.,

Persona de Contacto: Mr. Gary Gao

Teléfono: +8618610069839

Envíe su pregunta directamente a nosotros (0 / 3000)