logo
Главная страница ПродукцияМембрана MBR

PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment

Сертификация
Китай Sinomemb Environment Technology (beijing) Co., Сертификаты
Китай Sinomemb Environment Technology (beijing) Co., Сертификаты
Оставьте нам сообщение

PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment

PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment
PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment

Большие изображения :  PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment

Подробная информация о продукте:
Место происхождения: КИТАЙ
Фирменное наименование: SINOMEMB
Сертификация: NSF
Номер модели: SNU-HO-2-TF4
Оплата и доставка Условия:
Количество мин заказа: 5
Упаковывая детали: Стандартная экспортная упаковка

PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment

описание
Основные компоненты: MBR Название продукта: Ультрафильтрационная мембрана с полым волокном, система ультрафильтрационной системы, Мембранный мод
Размер пор: Индивидуальный., от 1 мкм до 0,05 мкм, 0,01 микрона, 1,0 мкм, 0,2 мкм Использование: Очистка сточных вод, жидкий фильтр, удаление бактерий, очистка
Модуль: ВНУТРЕННАЯ Номинальный размер поры: 00,03 мкм
Размер: 160 × 1810 мм Мембранный материал: PVDF
Площадь: 40m2
Выделить:

PVDF Hollow Fiber UF Membrane

,

0.03μm Pore Hollow Fiber UF Membrane

,

40m2 hollow fibre UF membrane

UF System Maintenance Operation Guide for Ultrafiltration Membrane SNU-HO-2-TF4
UF Membrane Element Size
PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment 0 PVDF Hollow Fiber UF Membrane 0.03μm Pore 40m2 Surface Area for Waste Water Treatment 1
Operation Guide
During UF system operation, avoid sudden pressure changes during startup, shutdown, operation, or cleaning procedures. Never exceed the maximum pressure limits specified in this manual to prevent:
  • Membrane breakage
  • Seal failure
  • Membrane shell cracking
  • Other serious damage
Our products undergo factory anti-corrosion treatment with membrane wires in semi-dry state. For manual operation:
  • Set water production rate to 50% of design capacity
  • Initial production water must be discharged - not suitable as product water
Product Usage Tips
Proper system startup and regular maintenance are essential for long-term membrane performance. Before operation:
  • Verify all valves, instruments, and pre-treatment equipment meet design specifications
  • Confirm proper function of signal transmission and power equipment
  • Ensure overall system meets safety and quality standards
Refer to the technical manual for system commissioning and testing procedures.
Disclaimer
Failure to follow specified operating limits voids our limited warranty. For inactive UF systems:
  • Inject protective solution into membrane modules
  • Perform anti-corrosion treatment
  • Prevent microbial growth to reduce maintenance costs
Partial OEM model parameters available for SINOMEMB® UF membranes.
Note: Custom element models (membrane performance, dimensions) available based on order quantity.

Контактная информация
Sinomemb Environment Technology (beijing) Co.,

Контактное лицо: Mr. Gary Gao

Телефон: +8618610069839

Оставьте вашу заявку (0 / 3000)

Другие продукты